Description

DLS 08 is a device able to delay analogue electric signals. The device is built according to a modular concept allowing delaying of up to 8 independent electric signals. Signal delay can be set to 2 to 1600 µs and it is also possible to amplify the signal (1×, 2×, 5×, 10×) and choose desired output signal mode; i.e. non-delayed signal, delayed signal, difference between delayed and non-delayed signal with an option to obtain inverted signal as well.The device contains 5th order active filters with limit frequencies of 500kHz/1 MHz. All parameters can be set up locally on the device or over TCP/IP connection as the device acts as a web server.

Parameters

Delay time

2 to 1600 µs

Resolution in time

1 µs

Output signal

OUT, INV-OUT,
IN, INV-IN,
DIFF, INV-DIFF

Delay Input – IN resp. Input -(INV-IN)

less than 0,5 µs

Gain

1×, 2×, 5×, 10×

Input voltage

0 to 5V

Input impedance

100 kΩ

Max. output voltage

± 5 V ± 5%

Low-pass filter

500 kHz / 1 MHz (default 1 MHz)

Max output load

500 Ω

Standard accuracy (DC)

0,30 to 0,35 %

Additional accuracy (DC)

0,01 % / °C

Setting time

15 min

Input, output connectors

BNC

 

System unit

Power

AC 230 V, 50/60 Hz

Fuse

400 mA, 5×20 mm

Dimmension

19″ × 3U × 280 mm

Weight

4 kg

No of ADM2306 modules

1 to 8

Remote control

Yes, TCP/IP protocol

Remote control SW

web server application

Related products